range of product | TeSys D | |
---|---|---|
range | TeSys | |
product or component type | Contactor | |
device short name | LC1D | |
contactor application | Motor control Resistive load | |
utilisation category | AC-1 AC-2 AC-4 AC-3 | |
control circuit type | AC at 50/60 Hz | |
poles description | 3P | |
pole contact composition | 3 NO | |
[Ie] rated operational current | 80 A (at <60 °C) at <= 440 V AC AC-1 for power circuit 65 A (at <60 °C) at <= 440 V AC AC-3 for power circuit | |
motor power kW | 30 kW at 440 V AC 50/60 Hz (AC-3) 11 kW at 400 V AC 50/60 Hz (AC-4) 30 kW at 380...400 V AC 50/60 Hz (AC-3) 30 kW at 415 V AC 50/60 Hz (AC-3) 37 kW at 1000 V AC 50/60 Hz (AC-3) 37 kW at 500 V AC 50/60 Hz (AC-3) 37 kW at 660...690 V AC 50/60 Hz (AC-3) 18.5 kW at 220...230 V AC 50/60 Hz (AC-3) | |
motor power hp | 10 hp at 230/240 V AC 60 Hz for 1P motors conforming to CSA 10 hp at 230/240 V AC 60 Hz for 1P motors conforming to UL 20 hp at 200/208 V AC 60 Hz for 3P motors conforming to CSA 20 hp at 200/208 V AC 60 Hz for 3P motors conforming to UL 20 hp at 230/240 V AC 60 Hz for 3P motors conforming to CSA 20 hp at 230/240 V AC 60 Hz for 3P motors conforming to UL 5 hp at 115 V AC 60 Hz for 1P motors conforming to CSA 5 hp at 115 V AC 60 Hz for 1P motors conforming to UL 50 hp at 460/480 V AC 60 Hz for 3P motors conforming to CSA 50 hp at 460/480 V AC 60 Hz for 3P motors conforming to UL 50 hp at 575/600 V AC 60 Hz for 3P motors conforming to CSA 50 hp at 575/600 V AC 60 Hz for 3P motors conforming to UL | |
[Uc] control circuit voltage | 120 V AC 50/60 Hz | |
connections - terminals | Control circuit: screw clamp terminal 1 x 1…4 mm²solid without cable end Control circuit: screw clamp terminal 2 x 1…4 mm²solid without cable end Control circuit: screw clamp terminal 1 x 1…4 mm²flexible with cable end Control circuit: screw clamp terminal 2 x 1…2.5 mm²flexible without cable end Power circuit: screw terminals Power circuit: screw clamp terminal 2 x 1…25 mm²solid without cable end Control circuit: screw clamp terminal 2 x 1…4 mm²flexible with cable end Power circuit: screw clamp terminal 1 x 1…35 mm²flexible without cable end Power circuit: screw clamp terminal 1 x 1…35 mm²solid without cable end Power circuit: screw clamp terminal 2 x 1…25 mm²flexible with cable end Power circuit: screw clamp terminal 2 x 1…35 mm²flexible without cable end Power circuit: screw clamp terminal 2 x 1…35 mm²solid with cable end |
coil technology | Without built-in bidirectional peak limiting diode suppressor | |
---|---|---|
protective cover | With | |
auxiliary contacts type | type mirror contact 1 NC conforming to IEC 60947-4-1 type mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1 | |
auxiliary contact composition | 1 NO + 1 NC | |
control circuit voltage limits | Drop-out: 0.3...0.6 Uc at 50/60 Hz (at <60 °C) Operational: 0.8...1.1 Uc at 50 Hz (at <60 °C) Operational: 0.85...1.1 Uc at 60 Hz (at <60 °C) | |
[Ui] rated insulation voltage | Control circuit: 600 V CSA certified Control circuit: 600 V UL certified Power circuit: 600 V CSA certified Power circuit: 600 V UL certified Control circuit: 690 V conforming to IEC 60947-1 Power circuit: 690 V conforming to IEC 60947-1 | |
[Uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947 | |
overvoltage category | III | |
mounting support | Rail Plate | |
flame retardance | V1 conforming to UL 94 | |
tightening torque | Control circuit: 1.2 N.m - on screw clamp terminal - with screwdriver flat Ø 6 mm Control circuit: 1.2 N.m - on screw clamp terminal - with screwdriver Philips No 2 Power circuit: 5 N.m - on screw clamp terminal - with screwdriver flat Ø 6 mm Power circuit: 5 N.m - on screw clamp terminal - with screwdriver flat Ø 8 mm | |
[Ue] rated operational voltage | Power circuit: <= 690 V AC 25...400 Hz | |
[Ith] conventional free air thermal current | 10 A (at 60 °C) for control circuit 80 A (at 60 °C) for power circuit | |
Irms rated making capacity | 140 A AC for control circuit conforming to IEC 60947-5-1 1000 A at 440 V for power circuit conforming to IEC 60947 | |
rated breaking capacity | 1000 A at 440 V for power circuit conforming to IEC 60947 | |
associated fuse rating | 10 A gG for control circuit conforming to IEC 60947-5-1 125 A gG at <= 690 V coordination type 1 for power circuit 125 A gG at <= 690 V coordination type 2 for power circuit | |
average impedance | - Ith 80 A 50 Hz for power circuit | |
power dissipation per pole | 6.4 W AC-1 | |
inrush power in VA | 140 VA cos phi 0.75 (at 20 °C) 160 VA cos phi 0.75 (at 20 °C) | |
hold-in power consumption in VA | 13 VA 50 Hz cos phi 0.3 (at 20 °C) 15 VA 60 Hz cos phi 0.3 (at 20 °C) | |
operating time | 12...26 ms closing 4...19 ms opening | |
safety reliability level | B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 | |
mechanical durability | 6000000 cycles | |
maximum operating rate | 3600 cyc/h 60 °C | |
minimum switching current | 5 mA for control circuit | |
minimum switching voltage | 17 V for control circuit | |
non-overlap time | 1.5 ms on de-energisation between NC and NO contacts 1.5 ms on energisation between NC and NO contacts | |
insulation resistance | > 10 MOhm for control circuit | |
terminals description ISO n°1 | (A1-A2)CO (13-14)NO (21-22)NC | |
height | 127 mm | |
width | 75 mm | |
depth | 119 mm | |
net weight | 1.4 kg |
standards | EN 60947-5-1 CSA C22.2 No 14 EN 60947-4-1 UL 508 IEC 60947-4-1 IEC 60947-5-1 | |
---|---|---|
product certifications | CCC UL BV CSA LROS (pending) GOST RINA GL DNV | |
IP degree of protection | IP2x conforming to IEC 60529 IP2x conforming to VDE 0106 | |
ambient air temperature for operation | -5…60 °C | |
ambient air temperature for storage | -60…80 °C | |
permissible ambient air temperature around the device | -40…70 °C at Uc | |
operating altitude | 3000 m without | |
fire resistance | 850 °C conforming to IEC 60695-2-1 | |
shock resistance | 10 gn contactor opened 15 gn contactor closed | |
vibration resistance | 2 gn 5…300 Hz contactor opened 4 gn 5…300 Hz contactor closed | |
heat dissipation | 4…5 W at 50/60 Hz for control circuit |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
EU RoHS Directive | Compliant EU RoHS Declaration | |
Toxic heavy metal free | Yes | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | ||
Environmental Disclosure | ||
Circularity Profile | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Warranty | 18 months |
---|