Close
C103MA050 View larger

C103MA050

Square D (Schneider Electric)

Square D (Schneider Electric)

3606482000346

New Factory Sealed - Original product -12 Months Warranty

Circuit breaker ComPact NSX100N, 50 kA at 415 VAC, MA trip unit 50 A, 3 poles 3d

More details

4 Items

IN STOCK

$369.62

Usually dispatched 1-2 days

Data sheet

Breaking Capacity Code Icu @ 415VN / 50kA
Poles Description3P
Trip Unit Rating50 A
Trip Unit NameMA
Protected Poles3t

More info

Main
range
ComPact
product name
ComPact NSX
range of product
ComPact NSX100...250
device short name
NSX100N
product or component type
Circuit breaker
device application
Motor
Number of poles
3P
protected poles description
3t
[In] rated current
50?A at 65??C
[Ue] rated operational voltage
690 V AC 50/60 Hz
network type
AC
network frequency
50/60 Hz
suitability for isolation
Yes conforming to EN/IEC 60947-2
utilisation category
Category A
[Icu] rated ultimate short-circuit breaking capacity
85?kA at 240 V AC 50/60 Hz conforming to UL 508
10?kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
35?kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2
20?kA at 600 V AC 50/60 Hz conforming to UL 508
50?kA at 480 V AC 50/60 Hz conforming to UL 508
36?kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
50?kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
50?kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
90?kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
Performance level
N 50?kA 415 V AC
trip unit name
MA
trip unit technology
Magnetic
trip unit protection functions
I
control type
Toggle
Circuit breaker mounting mode
Fixed
Complementary
[Ui] rated insulation voltage
800?V AC 50/60 Hz
[Uimp] rated impulse withstand voltage
8?kV
[Ics] rated service short-circuit breaking capacity
10?kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
35?kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
36?kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
50?kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
50?kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
90?kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
mechanical durability
50000?cycles
electrical durability
10000?cycles at 690 V In
20000?cycles at 690 V In/2
30000?cycles at 440 V In
50000?cycles at 440 V In/2
mounting support
Backplate
upside connection
Front
downside connection
Front
connection pitch
35?mm
protection type
I : for short-circuit protection (magnetic)
trip unit rating
50?A at 65??C
Short-time protection pick-up adjustment type Isd
Adjustable 9 settings
[Isd] Short-time protection pick-up adjustment range
6...14 x In
earth-leakage protection
Without
Number of slots for electrical auxiliaries
5 slot(s)
Width (W)
105?mm
Height (H)
161?mm
Depth (D)
86?mm
net weight
2.05?kg
Environment
standards
EN/IEC 60947
product certifications
CCC
EAC
Marine
overvoltage category
Class II
electrical shock protection class
Class II
pollution degree
3 conforming to IEC 60664-1
IP degree of protection
IP40 conforming to IEC 60529
IK degree of protection
IK07 conforming to IEC 62262
ambient air temperature for operation
-25?70??C
ambient air temperature for storage
-50?85??C
relative humidity
0?95?%
operating altitude
0...2000 m without derating
2000 m...5000 m with derating

30 other products in the same category

Schneider Partner

Schneider Electric Authorised distributor

Shipping Partner

DHL Express Delivery

Secure Payments

Scure site globalsign