3606482000346
New Factory Sealed - Original product -12 Months Warranty
4 Item Items
IN STOCK
Warning: Last items in stock!
Availability date:
Breaking Capacity Code Icu @ 415V | N / 50kA |
Poles Description | 3P |
Trip Unit Rating | 50 A |
Trip Unit Name | MA |
Protected Poles | 3t |
range | ComPact | |
---|---|---|
product name | ComPact NSX | |
range of product | ComPact NSX100...250 | |
device short name | NSX100N | |
product or component type | Circuit breaker | |
device application | Motor | |
Number of poles | 3P | |
protected poles description | 3t | |
[In] rated current | 50?A at 65??C | |
[Ue] rated operational voltage | 690 V AC 50/60 Hz | |
network type | AC | |
network frequency | 50/60 Hz | |
suitability for isolation | Yes conforming to EN/IEC 60947-2 | |
utilisation category | Category A | |
[Icu] rated ultimate short-circuit breaking capacity | 85?kA at 240 V AC 50/60 Hz conforming to UL 508 10?kA Icu at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 35?kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 20?kA at 600 V AC 50/60 Hz conforming to UL 508 50?kA at 480 V AC 50/60 Hz conforming to UL 508 36?kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 50?kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50?kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 90?kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 | |
Performance level | N 50?kA 415 V AC | |
trip unit name | MA | |
trip unit technology | Magnetic | |
trip unit protection functions | I | |
control type | Toggle | |
Circuit breaker mounting mode | Fixed |
[Ui] rated insulation voltage | 800?V AC 50/60 Hz | |
---|---|---|
[Uimp] rated impulse withstand voltage | 8?kV | |
[Ics] rated service short-circuit breaking capacity | 10?kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 35?kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 36?kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 50?kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 50?kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 90?kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 | |
mechanical durability | 50000?cycles | |
electrical durability | 10000?cycles at 690 V In 20000?cycles at 690 V In/2 30000?cycles at 440 V In 50000?cycles at 440 V In/2 | |
mounting support | Backplate | |
upside connection | Front | |
downside connection | Front | |
connection pitch | 35?mm | |
protection type | I : for short-circuit protection (magnetic) | |
trip unit rating | 50?A at 65??C | |
Short-time protection pick-up adjustment type Isd | Adjustable 9 settings | |
[Isd] Short-time protection pick-up adjustment range | 6...14 x In | |
earth-leakage protection | Without | |
Number of slots for electrical auxiliaries | 5 slot(s) | |
Width (W) | 105?mm | |
Height (H) | 161?mm | |
Depth (D) | 86?mm | |
net weight | 2.05?kg |
standards | EN/IEC 60947 | |
---|---|---|
product certifications | CCC EAC Marine | |
overvoltage category | Class II | |
electrical shock protection class | Class II | |
pollution degree | 3 conforming to IEC 60664-1 | |
IP degree of protection | IP40 conforming to IEC 60529 | |
IK degree of protection | IK07 conforming to IEC 62262 | |
ambient air temperature for operation | -25?70??C | |
ambient air temperature for storage | -50?85??C | |
relative humidity | 0?95?% | |
operating altitude | 0...2000 m without derating 2000 m...5000 m with derating |