trip unit - Micrologic 5.2 E - 40 A - 3 poles 3d

More details

25 Items

IN STOCK

$916.24

Usually dispatched 1-2 days

Data sheet

Poles Description3P
Trip Unit Rating40 A
Trip Unit NameMicrologic 5.2 A
Trip Unit TechnologyElectronic
Protected Poles3t
Frame TypeNSX 100/160/250 A

More info

Characteristics
Main
Commercial StatusCommercialised?
Range of productNSX100...250?
Circuit breaker applicationDistribution?
Poles description3P?
Protected poles description3t?
Network typeAC?
Network frequency50/60 Hz?
Trip unit nameMicrologic 5.2 E?
Trip unit technologyElectronic?
Trip unit protection functionsLSI?
Trip unit rating40 A ( 40 ?C )?
Protection typeInstantaneous short-circuit protection?
Overload protection (long time)?
Short time short-circuit protection?
Complementary
Mounting modeFixed?
[Ue] rated operational voltage690 V AC 50/60 Hz?
Long time pick-up adjstment type IrAdjustable?
Long time pick-up adjustment range18...40 A?
Long time delay adjustment typeAdjustable?
[tr] long-time delay adjustment0.5...16 s 6 x Ir?
0.35...11 s 7.2 x Ir?
15...400 s 1.5 x Ir?
Thermal memory20 minutes before and after tripping?
Short-time pick-up adjustment type IsdAdjustable?
[Isd] short-time pick-up adjustment range1.5...10 x Ir?
Short-time delay adjustment typeAdjustable?
[tsd] short-time delay adjustment range0...0.4 s?
Instantaneous pick-up adjustment type IiAdjustable?
Instantaneous pick-up adjustment range1.5...15 x In Compact NSX160?
1.5...15 x In Compact NSX100?
1.5...12 x In Compact NSX250?
Zone selective interlocking ZSIWith?
Communication of dataDemand current and power?
Energy metering?
Instantaneous and demand values?
Maintenance indicators?
Maximeters/minimeters?
Power quality?
Protection and alarm settings?
Time-stamped histories and event tables?
Display typeLCD display?
Type of measurementEnergy meter?
Electrical data recordingMaintenance indicators?
Environment
StandardsEN 60947-2?
IEC 60947-2?
NEMA AB1?
UL 508?
Product certificationsCSA?
UL?
IP degree of protectionIP40 conforming to IEC 60529?
Pollution degree3 conforming to IEC 60947-1?
Ambient air temperature for operation-25...70 ?C?
Ambient air temperature for storage-40...85 ?C?