Data sheet

Breaking Capacity Code Icu @ 415VL / 150 kA
Poles Description3P
[In] Rated Current160 A

More info

Characteristics
Main
Commercial StatusCommercialised?
Range of productNSX100...250?
Device short nameCompact NSX160F?
Circuit breaker nameCompact NSX160F?
Poles description3P?
Network typeAC?
Network frequency50/60 Hz?
[In] rated current160 A ( 40 ?C )?
[Ui] rated insulation voltage800 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage8 kV conforming to IEC 60947-2?
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking capacity codeF?
Breaking capacityIcu 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2?
35 kA at 480 V AC 50/60 Hz conforming to UL 508?
20 kA at 600 V AC 50/60 Hz conforming to NEMA AB1?
Icu 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2?
Icu 8 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2?
Icu 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2?
Icu 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2?
Icu 22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2?
85 kA at 240 V AC 50/60 Hz conforming to UL 508?
85 kA at 240 V AC 50/60 Hz conforming to NEMA AB1?
35 kA at 480 V AC 50/60 Hz conforming to NEMA AB1?
10 kA at 600 V AC 50/60 Hz conforming to UL 508?
[Ics] rated service breaking capacityIcs 8 kA 660/690 V AC 50/60 Hz conforming to IEC 60947-2?
Ics 30 kA 500 V AC 50/60 Hz conforming to IEC 60947-2?
Ics 22 kA 525 V AC 50/60 Hz conforming to IEC 60947-2?
Ics 85 kA 220/240 V AC 50/60 Hz conforming to IEC 60947-2?
Ics 36 kA 380/415 V AC 50/60 Hz conforming to IEC 60947-2?
Ics 35 kA 440 V AC 50/60 Hz conforming to IEC 60947-2?
Suitability for isolationYes conforming to IEC 60947-2?
Yes conforming to EN 60947-2?
Utilisation categoryCategory A?
Pollution degree3 conforming to IEC 60947-1?
Complementary
Control typeToggle?
Mounting modeFixed?
Mounting supportBackplate?
Upside connectionFront?
Downside connectionFront?
Mechanical durability40000 cycles conforming to IEC 60947-2?
Electrical durability7500 cycles 690 V AC 50/60 Hz In conforming to IEC 60947-2?
20000 cycles 440 V AC 50/60 Hz In conforming to IEC 60947-2?
15000 cycles 690 V AC 50/60 Hz In/2 conforming to IEC 60947-2?
10000 cycles 440 V AC 50/60 Hz In/2 conforming to IEC 60947-2?
Connection pitch35 mm?
Height161 mm?
Width105 mm?
Depth86 mm?
Environment
StandardsEN 60947-2?
IEC 60947-2?
NEMA AB1?
UL 508?
Product certificationsCSA?
UL?
IP degree of protectionIP40 conforming to IEC 60529?
IK degree of protectionIK07 conforming to IEC 62262?
Ambient air temperature for operation-35...70 ?C?
Ambient air temperature for storage-55...85 ?C?