Close
C16N32D160 View larger

C16N32D160

Square D (Schneider Electric)

Square D (Schneider Electric)

3606481998064

New Factory Sealed - Original product -12 Months Warranty

Circuit breaker Compact NSX160N - Micrologic 2.2 - 160 A - 3 poles 3d

More details

23 Items

IN STOCK

$802.53

Usually dispatched 1-2 days

Data sheet

Breaking Capacity Code Icu @ 415VN / 50kA
Poles Description3P
Trip Unit Rating160 A
Trip Unit NameMicrologic 2.2
[In] Rated Current160 A
Trip Unit TechnologyElectronic
Protected Poles3t

More info

Characteristics
Main
Commercial StatusCommercialised?
Product or component typeCircuit breaker?
Device short nameCompact NSX160N?
Circuit breaker applicationDistribution?
Poles description3P?
Protected poles description3t?
Network typeAC?
Network frequency50/60 Hz?
[In] rated current160 A ( 40 ?C )?
[Ui] rated insulation voltage800 V AC 50/60 Hz?
[Uimp] rated impulse withstand voltage8 kV?
[Ue] rated operational voltage690 V AC 50/60 Hz?
Breaking capacity codeN?
Breaking capacityIcu 90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2?
Icu 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2?
Icu 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2?
Icu 36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2?
90 kA at 240 V AC 50/60 Hz conforming to NEMA AB1?
50 kA at 480 V AC 50/60 Hz conforming to UL 508?
50 kA at 480 V AC 50/60 Hz conforming to NEMA AB1?
20 kA at 600 V AC 50/60 Hz conforming to NEMA AB1?
Icu 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2?
Icu 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2?
85 kA at 240 V AC 50/60 Hz conforming to UL 508?
10 kA at 600 V AC 50/60 Hz conforming to UL 508?
[Ics] rated service breaking capacityIcs 90 kA 220/240 V AC 50/60 Hz conforming to IEC 60947-2?
Ics 50 kA 440 V AC 50/60 Hz conforming to IEC 60947-2?
Ics 50 kA 380/415 V AC 50/60 Hz conforming to IEC 60947-2?
Ics 36 kA 500 V AC 50/60 Hz conforming to IEC 60947-2?
Ics 35 kA 525 V AC 50/60 Hz conforming to IEC 60947-2?
Ics 10 kA 660/690 V AC 50/60 Hz conforming to IEC 60947-2?
Suitability for isolationYes conforming to IEC 60947-2?
Yes conforming to EN 60947-2?
Utilisation categoryCategory A?
Trip unit nameMicrologic 2.2?
Trip unit technologyElectronic?
Trip unit protection functionsLSoI?
Trip unit rating160 A ( 40 ?C )?
Protection typeInstantaneous short-circuit protection?
Overload protection (long time)?
Short time short-circuit protection?
Pollution degree3 conforming to IEC 60664-1?
Complementary
Control typeToggle?
Mounting modeFixed?
Mounting supportBackplate?
Upside connectionFront?
Downside connectionFront?
Mechanical durability40000 cycles?
Electrical durability7500 cycles 690 V In conforming to IEC 60947-2?
20000 cycles 440 V In conforming to IEC 60947-2?
15000 cycles 690 V In/2 conforming to IEC 60947-2?
10000 cycles 440 V In/2 conforming to IEC 60947-2?
Connection pitch35 mm?
Local signallingLED 105 % Ir?
LED 90 % Ir?
LED ready?
Long time pick-up adjstment type IrAdjustable 9 settings?
Long time pick-up adjustment range0.9...1 x Io?
Long time delay adjustment typeFixed?
[tr] long-time delay adjustment400 s 1.5 x Ir?
16 s 6 x Ir?
11 s 7.2 x Ir?
Thermal memory20 minutes before and after tripping?
Short-time pick-up adjustment type IsdAdjustable 9 settings?
[Isd] short-time pick-up adjustment range1.5...10 x Ir?
Short-time delay adjustment typeFixed?
Instantaneous pick-up adjustment type IiFixed?
Instantaneous pick-up adjustment range2400 A?
Height161 mm?
Width105 mm?
Depth86 mm?
Product weight2.2 kg?
Environment
Electrical shock protection classClass II?
StandardsEN 60947-2?
IEC 60947-2?
NEMA AB1?
UL 508?
Product certificationsCSA?
UL?
IP degree of protectionIP40 conforming to IEC 60529?
IK degree of protectionIK07 conforming to IEC 62262?
Ambient air temperature for operation-35...70 ?C?
Ambient air temperature for storage-55...85 ?C?

30 other products in the same category

Schneider Partner

Schneider Electric Authorised distributor

Shipping Partner

DHL Express Delivery

Secure Payments

Scure site globalsign

Close