Close
C40H32D400 View larger

C40H32D400

Square D (Schneider Electric)

Square D (Schneider Electric)

3606482002784

New Factory Sealed - Original product -12 Months Warranty

Circuit breaker Compact NSX400H - Micrologic 2.3 - 400 A - 3 poles 3d

More details

21 Items

IN STOCK

$1,417.01

Usually dispatched 1-2 days

Data sheet

Breaking Capacity Code Icu @ 415VH / 70kA
Poles Description3P
Trip Unit Rating400 A
Trip Unit NameMicrologic 2.3
[In] Rated Current400 A
Trip Unit TechnologyElectronic
Protected Poles3t

More info

Characteristics
Main
Commercial StatusCommercialised?
Product or component typeCircuit breaker?
Device short nameCompact NSX400H?
Circuit breaker applicationDistribution?
Poles description3P?
Protected poles description3t?
Network typeAC?
Network frequency50/60 Hz?
[In] rated current400 A ( 40 ?C )?
[Ui] rated insulation voltage800 V AC 50/60 Hz?
[Uimp] rated impulse withstand voltage8 kV?
[Ue] rated operational voltage690 V AC 50/60 Hz?
Breaking capacity codeH?
Breaking capacityIcu 20 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2?
20 kA at 600 V AC 50/60 Hz conforming to UL 508?
Icu 70 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2?
Icu 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2?
Icu 50 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2?
Icu 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2?
Icu 100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2?
65 kA at 480 V AC 50/60 Hz conforming to UL 508?
65 kA at 480 V AC 50/60 Hz conforming to NEMA AB1?
35 kA at 600 V AC 50/60 Hz conforming to NEMA AB1?
100 kA at 240 V AC 50/60 Hz conforming to NEMA AB1?
85 kA at 240 V AC 50/60 Hz conforming to UL 508?
[Ics] rated service breaking capacityIcs 70 kA 380/415 V AC 50/60 Hz conforming to IEC 60947-2?
Ics 65 kA 440 V AC 50/60 Hz conforming to IEC 60947-2?
Ics 50 kA 500 V AC 50/60 Hz conforming to IEC 60947-2?
Ics 100 kA 220/240 V AC 50/60 Hz conforming to IEC 60947-2?
Ics 10 kA 660/690 V AC 50/60 Hz conforming to IEC 60947-2?
Ics 11 kA 525 V AC 50/60 Hz conforming to IEC 60947-2?
Suitability for isolationYes conforming to IEC 60947-2?
Yes conforming to EN 60947-2?
Utilisation categoryCategory A?
Trip unit nameMicrologic 2.3?
Trip unit technologyElectronic?
Trip unit protection functionsLSoI?
Trip unit rating400 A ( 40 ?C )?
Protection typeInstantaneous short-circuit protection?
Overload protection (long time)?
Short time short-circuit protection?
Pollution degree3 conforming to IEC 60664-1?
Complementary
Control typeToggle?
Mounting modeFixed?
Mounting supportBackplate?
Upside connectionFront?
Downside connectionFront?
Mechanical durability15000 cycles?
Electrical durability6000 cycles 690 V In/2 conforming to IEC 60947-2?
6000 cycles 440 V In conforming to IEC 60947-2?
3000 cycles 690 V In conforming to IEC 60947-2?
12000 cycles 440 V In/2 conforming to IEC 60947-2?
Connection pitch45 mm?
Local signallingLED 105 % Ir?
LED 90 % Ir?
LED ready?
Long time pick-up adjstment type IrAdjustable 9 settings?
Long time pick-up adjustment range0.9...1 x Io?
Long time delay adjustment typeFixed?
[tr] long-time delay adjustment16 s 6 x Ir?
Thermal memory20 minutes before and after tripping?
Short-time pick-up adjustment type IsdAdjustable 9 settings?
[Isd] short-time pick-up adjustment range1.5...10 x Ir?
Short-time delay adjustment typeFixed?
Instantaneous pick-up adjustment type IiFixed?
Instantaneous pick-up adjustment range4800 A?
Height255 mm?
Width140 mm?
Depth110 mm?
Product weight6.05 kg?
Environment
Electrical shock protection classClass II?
StandardsEN 60947-2?
IEC 60947-2?
NEMA AB1?
UL 508?
Product certificationsCSA?
UL?
IP degree of protectionIP40 conforming to IEC 60529?
IK degree of protectionIK07 conforming to IEC 62262?
Ambient air temperature for operation-35...70 ?C?
Ambient air temperature for storage-55...85 ?C?

30 other products in the same category

Schneider Partner

Schneider Electric Authorised distributor

Shipping Partner

DHL Express Delivery

Secure Payments

Scure site globalsign

Close