Product successfully added to your shopping cart
Quantity:
Total
There are 0 items in your cart. There is 1 item in your cart.
Total products:
Total shipping: To be determined
Total:
3389118204003
New Factory Sealed - Original product -12 Months Warranty
4 Item Items
IN STOCK
Warning: Last items in stock!
Availability date:
Poles Description | 3P |
Trip Unit Rating | 9…13A |
Trip Unit Technology | Thermal-Magnetic |
Connection Terminals | Lugs |
Control Type | Rotary Knob |
Motor Power @400/415 v | 5.5KW |
range | TeSys | |
---|---|---|
product name | TeSys GV3 | |
device short name | GV3P | |
product or component type | Circuit breaker | |
device application | Motor | |
trip unit technology | Thermal-magnetic |
poles description | 3P | |
---|---|---|
network type | AC | |
utilisation category | AC-3 conforming to IEC 60947-4-1 Category A conforming to IEC 60947-2 | |
network frequency | 50/60 Hz conforming to IEC 60947-4-1 | |
fixing mode | Clipped on 35 mm symmetrical DIN rail Screwed on panel (with 3 x M4 screws) | |
operating position | Any position | |
motor power kW | 11 kW at 690 V AC 50/60 Hz 7.5 kW at 500 V AC 50/60 Hz 5.5 kW at 400/415 V AC 50/60 Hz | |
breaking capacity | 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 | |
[Ics] rated service short-circuit breaking capacity | 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 | |
control type | Rotary knob | |
[In] rated current | 9...13 A | |
trip unit rating | 9...13 A | |
magnetic tripping current | 182 A | |
[Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 | |
[Ui] rated insulation voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 | |
[Ith] conventional free air thermal current | 13 A conforming to IEC 60947-4-1 | |
[Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 | |
power dissipation per pole | 8 W | |
mechanical durability | 50000 cycles | |
electrical durability | 50000 cycles for AC-3 at 440 V In | |
operating rate | 25 cyc/h | |
rated duty | Continuous conforming to IEC 60947-4-1 | |
connection pitch | 17.5 mm without spreaders | |
connections - terminals | Lugs-ring terminals external diameter : 6 mm Bars 6 x 13.5 mm | |
tightening torque | 6 N.m on bars M6 screw type 6 N.m on lugs-ring terminals M6 screw type | |
suitability for isolation | Yes conforming to IEC 60947-1 | |
phase failure sensitivity | Yes conforming to IEC 60947-4-1 | |
height | 132 mm | |
width | 55 mm | |
depth | 136 mm | |
product weight | 0.96 kg |
standards | EN/IEC 60947-1 CSA C22.2 No 14-05 type E EN/IEC 60947-2 UL 508 type E EN/IEC 60947-4-1 | |
---|---|---|
product certifications | RINA CSA DNV BV EAC CCC LROS (pending) GL ATEX UL | |
protective treatment | TH | |
IP degree of protection | IP20 conforming to IEC 60529 | |
IK degree of protection | IK09 | |
ambient air temperature for operation | -20...60 °C | |
ambient air temperature for storage | -40...80 °C | |
fire resistance | 960 °C conforming to IEC 60695-2-1 | |
operating altitude | 3000 m |
Warranty period | 18 months |
---|