Close
GV3P65 View larger

GV3P65

Square D (Schneider Electric)

Square D (Schneider Electric)

3389118348639

New Factory Sealed - Original product -12 Months Warranty

TeSys GV3-Circuit breaker-thermal-magnetic - 48…65A - EverLink BTR connectors

More details

3 Items

IN STOCK

$248.32

Usually dispatched 1-2 days

Data sheet

Poles Description3P
Trip Unit Rating48…65A
Trip Unit TechnologyThermal-Magnetic
Connection TerminalsEverLink BTR
Control TypeRotary Knob
Motor Power @400/415 v30KW

More info

  • Main
    range
    TeSys
    product name
    TeSys GV3
    device short name
    GV3P
    product or component type
    Circuit breaker
    device application
    Motor
    trip unit technology
    Thermal-magnetic
    Complementary
    poles description
    3P
    network type
    AC
    utilisation category
    AC-3 conforming to IEC 60947-4-1
    Category A conforming to IEC 60947-2
    network frequency
    50/60 Hz conforming to IEC 60947-4-1
    fixing mode
    Clipped on 35 mm symmetrical DIN rail
    Screwed on panel (with 3 x M4 screws)
    operating position
    Any position
    motor power kW
    45 kW at 500 V AC 50/60 Hz
    55 kW at 690 V AC 50/60 Hz
    30 kW at 400/415 V AC 50/60 Hz
    breaking capacity
    50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
    100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
    50 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
    6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
    12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
    [Ics] rated service short-circuit breaking capacity
    100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
    100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
    50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
    50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
    100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
    control type
    Rotary knob
    [In] rated current
    48...65 A
    trip unit rating
    48...65 A
    magnetic tripping current
    910 A
    [Ue] rated operational voltage
    690 V AC 50/60 Hz conforming to IEC 60947-2
    [Ui] rated insulation voltage
    690 V AC 50/60 Hz conforming to IEC 60947-2
    [Ith] conventional free air thermal current
    65 A conforming to IEC 60947-4-1
    [Uimp] rated impulse withstand voltage
    6 kV conforming to IEC 60947-2
    power dissipation per pole
    8 W
    mechanical durability
    50000 cycles
    electrical durability
    50000 cycles for AC-3 at 440 V In
    operating rate
    25 cyc/h
    rated duty
    Continuous conforming to IEC 60947-4-1
    connections - terminals
    EverLink BTR screw connectors 2 cable(s) 1...25 mm² solid
    EverLink BTR screw connectors 2 cable(s) 1...25 mm² flexible without cable end
    EverLink BTR screw connectors 2 cable(s) 1...25 mm² flexible with cable end
    tightening torque
    5 N.m on EverLink BTR screw connectors for cable 25 mm²
    8 N.m on EverLink BTR screw connectors for cable 35 mm²
    suitability for isolation
    Yes conforming to IEC 60947-1
    phase failure sensitivity
    Yes conforming to IEC 60947-4-1
    height
    132 mm
    width
    55 mm
    depth
    136 mm
    product weight
    0.96 kg
    Environment
    standards
    EN/IEC 60947-4-1
    CSA C22.2 No 14-05 type E
    EN/IEC 60947-1
    EN/IEC 60947-2
    UL 508 type E
    product certifications
    LROS (pending)
    CCC
    ATEX
    UL
    RINA
    GL
    EAC
    BV
    CSA
    DNV
    protective treatment
    TH
    IP degree of protection
    IP20 conforming to IEC 60529
    IK degree of protection
    IK09
    ambient air temperature for operation
    -20...60 °C
    ambient air temperature for storage
    -40...80 °C
    fire resistance
    960 °C conforming to IEC 60695-2-1
    operating altitude
    3000 m
    Contractual warranty
    Warranty period
    18 months

Also Bought Products

9 other products in the same category

Schneider Partner

Schneider Electric Authorised distributor

Shipping Partner

DHL Express Delivery

Secure Payments

Scure site globalsign

Close