Close
Reduced price! LV429782 View larger

LV429782

Square D (Schneider Electric)

67_1417005729

Square D (Schneider Electric)

3606480007439

New

Circuit breaker Compact NSX100F - Micrologic 2.2 - 40 A - 4 poles 4d

More details

25 Items

IN STOCK

USD $642.66

USD $803.33

-20%

Delivery 5 days

Data sheet

Poles Description4P
[In] Rated Current100 A
Breaking Capacity Code Icu @ 415VF / 36kA
Trip Unit Rating40 A
Trip Unit NameMicrologic 2.2
Trip Unit TechnologyElectronic
Protected Poles3t

More info

Characteristics
Main
Commercial StatusCommercialised 
Product or component typeCircuit breaker 
Device short nameCompact NSX100F 
Circuit breaker applicationDistribution 
Poles description4P 
Protected poles description3t 
3t + N/2 
4t 
Neutral positionLeft 
Network typeAC 
Network frequency50/60 Hz 
[In] rated current100 A ( 40 °C ) 
[Ui] rated insulation voltage800 V AC 50/60 Hz 
[Uimp] rated impulse withstand voltage8 kV 
[Ue] rated operational voltage690 V AC 50/60 Hz 
Breaking capacity code
Breaking capacityIcu 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 
Icu 8 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 
Icu 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 
Icu 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 
Icu 25 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 
Icu 22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 
85 kA at 240 V AC 50/60 Hz conforming to UL 508 
85 kA at 240 V AC 50/60 Hz conforming to NEMA AB1 
8 kA at 600 V AC 50/60 Hz conforming to NEMA AB1 
35 kA at 480 V AC 50/60 Hz conforming to NEMA AB1 
25 kA at 480 V AC 50/60 Hz conforming to UL 508 
10 kA at 600 V AC 50/60 Hz conforming to UL 508 
[Ics] rated service breaking capacityIcs 12.5 kA 500 V AC 50/60 Hz conforming to IEC 60947-2 
Ics 85 kA 220/240 V AC 50/60 Hz conforming to IEC 60947-2 
Ics 4 kA 660/690 V AC 50/60 Hz conforming to IEC 60947-2 
Ics 36 kA 380/415 V AC 50/60 Hz conforming to IEC 60947-2 
Ics 35 kA 440 V AC 50/60 Hz conforming to IEC 60947-2 
Ics 11 kA 525 V AC 50/60 Hz conforming to IEC 60947-2 
Suitability for isolationYes conforming to IEC 60947-2 
Yes conforming to EN 60947-2 
Utilisation categoryCategory A 
Trip unit nameMicrologic 2.2 
Trip unit technologyElectronic 
Trip unit protection functionsLSoI 
Trip unit rating40 A ( 40 °C ) 
Protection typeInstantaneous short-circuit protection 
Overload protection (long time) 
Short time short-circuit protection 
Pollution degree3 conforming to IEC 60664-1 
Complementary
Control typeToggle 
Mounting modeFixed 
Mounting supportBackplate 
Upside connectionFront 
Downside connectionFront 
Mechanical durability50000 cycles 
Electrical durability50000 cycles 440 V In/2 conforming to IEC 60947-2 
30000 cycles 440 V In conforming to IEC 60947-2 
20000 cycles 690 V In/2 conforming to IEC 60947-2 
10000 cycles 690 V In conforming to IEC 60947-2 
Connection pitch35 mm 
Local signallingLED 105 % Ir 
LED 90 % Ir 
LED ready 
Neutral protection settingNo protection 3t 
1 x Ir 4t 
0.5 x Ir 3t + N/2 
Long time pick-up adjstment type IrAdjustable 9 settings 
Long time pick-up adjustment range0.9...1 x Io 
Long time delay adjustment typeFixed 
[tr] long-time delay adjustment400 s 1.5 x Ir 
16 s 6 x Ir 
11 s 7.2 x Ir 
Thermal memory20 minutes before and after tripping 
Short-time pick-up adjustment type IsdAdjustable 9 settings 
[Isd] short-time pick-up adjustment range1.5...10 x Ir 
Short-time delay adjustment typeFixed 
Instantaneous pick-up adjustment type IiFixed 
Instantaneous pick-up adjustment range1500 A 
Height161 mm 
Width140 mm 
Depth86 mm 
Product weight2.4 kg 
Environment
Electrical shock protection classClass II 
StandardsEN 60947-2 
IEC 60947-2 
NEMA AB1 
UL 508 
Product certificationsCSA 
UL 
IP degree of protectionIP40 conforming to IEC 60529 
IK degree of protectionIK07 conforming to IEC 62262 
Ambient air temperature for operation-35...70 °C 
Ambient air temperature for storage-55...85 °C 