Close
LV431643 View larger

LV431643

Square D (Schneider Electric)

89_29241010

Square D (Schneider Electric)

3606480014314

New Factory Sealed - Original product -12 Months Warranty

Circuit breaker Compact NSX250F - TMD - 125 A - 4 poles 3d

More details

25 Items

IN STOCK

$863.69 TAX INCLUDED

Usually dispatched 1-2 days

Data sheet

Breaking Capacity Code Icu @ 415VF / 36kA
Poles Description4P
Trip Unit Rating125 A
Trip Unit NameTM-D
[In] Rated Current250 A
Trip Unit TechnologyThermal-Magnetic
Protected Poles3t

More info

Characteristics
Main
Commercial StatusCommercialised 
Product or component typeCircuit breaker 
Device short nameCompact NSX250F 
Circuit breaker applicationDistribution 
Poles description4P 
Protected poles description3t 
Neutral positionLeft 
Network typeAC 
Network frequency50/60 Hz 
[In] rated current250 A ( 40 °C ) 
[Ui] rated insulation voltage800 V AC 50/60 Hz 
[Uimp] rated impulse withstand voltage8 kV 
[Ue] rated operational voltage690 V AC 50/60 Hz 
Breaking capacity code
Breaking capacity15 kA at 600 V AC 50/60 Hz conforming to UL 508 
Icu 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 
35 kA at 480 V AC 50/60 Hz conforming to UL 508 
20 kA at 600 V AC 50/60 Hz conforming to NEMA AB1 
Icu 85 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 
Icu 8 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2 
Icu 36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 
Icu 35 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 
Icu 22 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 
85 kA at 240 V AC 50/60 Hz conforming to UL 508 
85 kA at 240 V AC 50/60 Hz conforming to NEMA AB1 
35 kA at 480 V AC 50/60 Hz conforming to NEMA AB1 
[Ics] rated service breaking capacityIcs 8 kA 660/690 V AC 50/60 Hz conforming to IEC 60947-2 
Ics 30 kA 500 V AC 50/60 Hz conforming to IEC 60947-2 
Ics 22 kA 525 V AC 50/60 Hz conforming to IEC 60947-2 
Ics 85 kA 220/240 V AC 50/60 Hz conforming to IEC 60947-2 
Ics 36 kA 380/415 V AC 50/60 Hz conforming to IEC 60947-2 
Ics 35 kA 440 V AC 50/60 Hz conforming to IEC 60947-2 
Suitability for isolationYes conforming to IEC 60947-2 
Yes conforming to EN 60947-2 
Utilisation categoryCategory A 
Trip unit nameTM-D 
Trip unit technologyThermal-magnetic 
Trip unit protection functionsLI 
Trip unit rating125 A ( 40 °C ) 
Protection typeOverload protection (thermal) 
Short-circuit protection (magnetic) 
Pollution degree3 conforming to IEC 60664-1 
Complementary
Control typeToggle 
Mounting modeFixed 
Mounting supportBackplate 
Upside connectionFront 
Downside connectionFront 
Mechanical durability20000 cycles 
Electrical durability5000 cycles 690 V In conforming to IEC 60947-2 
20000 cycles 440 V In/2 conforming to IEC 60947-2 
10000 cycles 690 V In/2 conforming to IEC 60947-2 
10000 cycles 440 V In conforming to IEC 60947-2 
Connection pitch35 mm 
Local signallingPositive contact indication 
Neutral protection settingNo protection 3t 
Long time pick-up adjstment type IrAdjustable 
Long time pick-up adjustment range0.7...1 x In 
Long time delay adjustment typeFixed 
[tr] long-time delay adjustment15 s 6 x Ir 
120...400 s 1.5 x In 
Short-time pick-up adjustment type IsdAdjustable 
[Isd] short-time pick-up adjustment range5...10 x In 
Short-time delay adjustment typeFixed 
Height161 mm 
Width140 mm 
Depth86 mm 
Product weight2.8 kg 
Environment
Electrical shock protection classClass II 
StandardsEN 60947-2 
IEC 60947-2 
NEMA AB1 
UL 508 
Product certificationsCSA 
UL 
IP degree of protectionIP40 conforming to IEC 60529 
IK degree of protectionIK07 conforming to IEC 62262 
Ambient air temperature for operation-35...70 °C 
Ambient air temperature for storage-55...85 °C 

30 other products in the same category

Schneider Partner

Schneider Electric Authorised distributor

Shipping Partner

DHL Express Delivery

Secure Payments

Scure site globalsign

Close