Close
LV430629 View larger

LV430629

Square D (Schneider Electric)

115_2115339028

Square D (Schneider Electric)

3606480011320

New Factory Sealed - Original product -12 Months Warranty

switch-disconnector Compact NSX160NA - 160 A - 3P

More details

25 Items

IN STOCK

$432.02 TAX INCLUDED

Usually dispatched 1-2 days

Data sheet

Poles Description3P
[In] Rated Current160 A

More info

Characteristics
Main
Commercial StatusCommercialised 
Device short nameCompact NSX160NA 
Poles description3P 
Network typeAC 
DC 
Network frequency50/60 Hz 
[Ie] rated operational currentDC-23A : 160 A DC 750 V 3 poles in series 
DC-23A : 160 A DC 500 V 2 poles in series 
DC-23A : 160 A DC 250 V 1 pole 
DC-22A : 160 A DC 750 V 3 poles in series 
DC-22A : 160 A DC 500 V 2 poles in series 
DC-22A : 160 A DC 250 V 1 pole 
AC-23A : 160 A AC 50/60 Hz 660/690 V 
AC-23A : 160 A AC 50/60 Hz 500/525 V 
AC-23A : 160 A AC 50/60 Hz 480 V NEMA AB1 
AC-23A : 160 A AC 50/60 Hz 440/480 V 
AC-23A : 160 A AC 50/60 Hz 380/415 V 
AC-23A : 160 A AC 50/60 Hz 220/240 V 
AC-22A : 160 A AC 50/60 Hz 660/690 V 
AC-22A : 160 A AC 50/60 Hz 500/525 V 
AC-22A : 160 A AC 50/60 Hz 480 V NEMA AB1 
AC-22A : 160 A AC 50/60 Hz 440/480 V 
AC-22A : 160 A AC 50/60 Hz 380/415 V 
AC-22A : 160 A AC 50/60 Hz 220/240 V 
[Ui] rated insulation voltage800 V AC 50/60 Hz conforming to IEC 60947-3
[Uimp] rated impulse withstand voltage8 kV conforming to IEC 60947-3 
[Ith] conventional free air thermal current160 A ( 60 °C ) 
[Icm] rated short-circuit making capacity3.6 kA switch-disconnector alone 
330 kA with upstream protection circuit breaker
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-3
Breaking capacity codeNA 
Suitability for isolationYes conforming to IEC 60947-3 
Yes conforming to EN 60947-3 
Contact position indicatorYes 
Visible breakNo 
Pollution degree3 conforming to IEC 60664-1 
Complementary
Control typeToggle 
Mounting modeFixed 
Mounting supportBackplate 
Upside connectionFront 
Downside connectionFront 
[Icw] rated short-time withstand current2.5 kA ( 3 s ) conforming to IEC 60947-3 
2.5 kA ( 1 s ) conforming to IEC 60947-3 
0.96 kA ( 20 s ) conforming to IEC 60947-3 
Mechanical durability40000 cycles conforming to IEC 60947-3 
Electrical durabilityAC-23A : 5000 cycles 690 V AC 50/60 Hz In conforming to IEC 60947-3 
AC-23A : 5000 cycles 500 V DC In (2 poles in series) conforming to IEC 60947-3 
AC-23A : 30000 cycles 440 V AC 50/60 Hz In/2 conforming to IEC 60947-3 
AC-23A : 15000 cycles 440 V AC 50/60 Hz In conforming to IEC 60947-3 
AC-23A : 10000 cycles 690 V AC 50/60 Hz In/2 conforming to IEC 60947-3 
AC-23A : 10000 cycles 250 V DC In/2 (1 pole) conforming to IEC 60947-3 
AC-22A : 5000 cycles 690 V AC 50/60 Hz In conforming to IEC 60947-3 
AC-22A : 5000 cycles 500 V DC In (2 poles in series) conforming to IEC 60947-3 
AC-22A : 30000 cycles 440 V AC 50/60 Hz In/2 conforming to IEC 60947-3 
AC-22A : 15000 cycles 440 V AC 50/60 Hz In conforming to IEC 60947-3 
AC-22A : 10000 cycles 690 V AC 50/60 Hz In/2 conforming to IEC 60947-3 
AC-22A : 10000 cycles 250 V DC In/2 (1 pole) conforming to IEC 60947-3 
Connection pitch35 mm 
Height161 mm 
Width105 mm 
Depth86 mm 
Product weight1.8 kg 
Environment
StandardsEN 60947-2 
IEC 60947-2 
NEMA AB1 
UL 508 
Product certificationsCSA 
UL 
IP degree of protectionIP40 conforming to IEC 60529 
IK degree of protectionIK07 conforming to IEC 62262 
Electrical shock protection classClass II 
Ambient air temperature for operation-35...70 °C 
Ambient air temperature for storage-55...85 °C 