C16N4TM100 - circuit breaker Compact NSX160N - TMD - 100 A - 4 poles 4d
zoom_out_map
chevron_left chevron_right

C16N4TM100

Circuit breaker Compact NSX160N - TMD - 100 A - 4 poles 4d

$747.22

747.22 Tax excluded

 IN STOCK
SECURE ENCRYPTED SITE
SHIP TO 50+ COUNTRIES
30 DAYS RETURNS

Characteristics
Main
Commercial Status Commercialised?
Product or component type Circuit breaker?
Device short name Compact NSX160N?
Circuit breaker application Distribution?
Poles description 4P?
Protected poles description 4t?
Neutral position Left?
Network type AC?
Network frequency 50/60 Hz?
[In] rated current 160 A ( 40 ?C )?
[Ui] rated insulation voltage 800 V AC 50/60 Hz?
[Uimp] rated impulse withstand voltage 8 kV?
[Ue] rated operational voltage 690 V AC 50/60 Hz?
Breaking capacity code N?
Breaking capacity Icu 90 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2?
Icu 50 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2?
Icu 50 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2?
Icu 36 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2?
90 kA at 240 V AC 50/60 Hz conforming to NEMA AB1?
50 kA at 480 V AC 50/60 Hz conforming to UL 508?
50 kA at 480 V AC 50/60 Hz conforming to NEMA AB1?
20 kA at 600 V AC 50/60 Hz conforming to NEMA AB1?
Icu 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2?
Icu 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2?
85 kA at 240 V AC 50/60 Hz conforming to UL 508?
10 kA at 600 V AC 50/60 Hz conforming to UL 508?
[Ics] rated service breaking capacity Ics 90 kA 220/240 V AC 50/60 Hz conforming to IEC 60947-2?
Ics 50 kA 440 V AC 50/60 Hz conforming to IEC 60947-2?
Ics 50 kA 380/415 V AC 50/60 Hz conforming to IEC 60947-2?
Ics 36 kA 500 V AC 50/60 Hz conforming to IEC 60947-2?
Ics 35 kA 525 V AC 50/60 Hz conforming to IEC 60947-2?
Ics 10 kA 660/690 V AC 50/60 Hz conforming to IEC 60947-2?
Suitability for isolation Yes conforming to IEC 60947-2?
Yes conforming to EN 60947-2?
Utilisation category Category A?
Trip unit name TM-D?
Trip unit technology Thermal-magnetic?
Trip unit protection functions LI?
Trip unit rating 100 A ( 40 ?C )?
Protection type Overload protection (thermal)?
Short-circuit protection (magnetic)?
Pollution degree 3 conforming to IEC 60664-1?
Complementary
Control type Toggle?
Mounting mode Fixed?
Mounting support Backplate?
Upside connection Front?
Downside connection Front?
Mechanical durability 40000 cycles?
Electrical durability 7500 cycles 690 V In conforming to IEC 60947-2?
20000 cycles 440 V In conforming to IEC 60947-2?
15000 cycles 690 V In/2 conforming to IEC 60947-2?
10000 cycles 440 V In/2 conforming to IEC 60947-2?
Connection pitch 35 mm?
Local signalling Positive contact indication?
Neutral protection setting 1 x Ir 4t?
Long time pick-up adjstment type Ir Adjustable?
Long time pick-up adjustment range 0.7...1 x In?
Long time delay adjustment type Fixed?
[tr] long-time delay adjustment 15 s 6 x Ir?
120...400 s 1.5 x In?
Short-time pick-up adjustment type Isd Fixed?
[Isd] short-time pick-up adjustment range 1250 A?
Short-time delay adjustment type Fixed?
Height 161 mm?
Width 140 mm?
Depth 86 mm?
Product weight 2.6 kg?
Environment
Electrical shock protection class Class II?
Standards EN 60947-2?
IEC 60947-2?
NEMA AB1?
UL 508?
Product certifications CSA?
UL?
IP degree of protection IP40 conforming to IEC 60529?
IK degree of protection IK07 conforming to IEC 62262?
Ambient air temperature for operation -35...70 ?C?
Ambient air temperature for storage -55...85 ?C?
EAN13 3606481998194
Poles Description
4P
Trip Unit Rating
100 A
Trip Unit Name
TM-D
[In] Rated Current
160 A
Breaking Capacity Code Icu @ 415V
N / 50kA
Trip Unit Technology
Thermal-Magnetic
Protected Poles
4t

Returns Policy

You may return most new, unopened items within 30 days of delivery for a full refund. We'll also pay the return shipping costs if the return is a result of our error (you received an incorrect or defective item, etc.).

You should expect to receive your refund within four weeks of giving your package to the return shipper, however, in many cases you will receive a refund more quickly. This time period includes the transit time for us to receive your return from the shipper (5 to 10 business days), the time it takes us to process your return once we receive it (3 to 5 business days), and the time it takes your bank to process our refund request (5 to 10 business days).

If you need to return an item, simply login to your account, view the order using the 'Complete Orders' link under the My Account menu and click the Return Item(s) button. We'll notify you via e-mail of your refund once we've received and processed the returned item.

Shipping

We can ship to virtually any address in the world. Note that there are restrictions on some products, and some products cannot be shipped to international destinations.

When you place an order, we will estimate shipping and delivery dates for you based on the availability of your items and the shipping options you choose. Depending on the shipping provider you choose, shipping date estimates may appear on the shipping quotes page.

Please also note that the shipping rates for many items we sell are weight-based. The weight of any such item can be found on its detail page. To reflect the policies of the shipping companies we use, all weights will be rounded up to the next full pound.

  • "Excellent products and excellent service." - Josephine
  • "Excellent value. High quality products at reasonable prices." - Warren
  • "Outstanding customer service." - Jack
  • "You're the best! Thank you!" - Tatiana